1C bitumen thick coating
1C bitumen-thick paint
SRFCOAT-1K-BITUMEN-30LTR
Register now and access more than 125,000 products
Flexible, stretchable and crack-bridging
Filled with expandable polystyrene
- Lower density
- Lighter hobbock pail for good handling
Can be applied with a brush, by spraying or with a spatula
- User-friendly application
- Broad range of applications
Ready-to-use sealing for easy and fast application
The cured coating is non-rotting and is resistant to all common chemicals found in soil.
Solvent-free
The minimum processing temperature is +5°C. It is essential that the effects of rain and frost and water stresses are prevented until both coats have completely dried. Direct sunlight should be avoided. Ideally, surfaces not to be coated (e.g. in an area to be subsequently plastered) should be covered, as the bitumen compound cannot be removed without leaving residue. During application, it is recommended that you wear personal protective equipment (safety goggles, art. no. 0892 102 ff./gloves, art. no. 0899 435 ff.).
Breathing protection (particulate filter P2) is also required for spraying. In principle, other possible valid specifications or regulations regarding the operation of machines, environmental protection or personal protective equipment must be observed during application.
The usage instructions are recommendations based on the tests we have conducted and our experience; carry out your own tests before each application. Due to the large number of applications and storage and processing conditions, we do not assume any liability for a specific application result. Insofar as our free customer service provides technical information or acts as an advisory service, no responsibility is assumed by this service except where the advice or information given falls within the scope of our specified, contractually agreed service or the advisor was acting deliberately. We guarantee the consistent quality of our products. We reserve the right to make technical changes and carry out further development.
Datasheets(X)
For secure, permanent sealing based on DIN 18533-3. Can be used in the Würth building waterproofing system for permanent sealing of foundations and cellars, for construction components in contact with the ground, for patios and balconies without underlying structures, and in wet rooms. Not suitable for water penetrating from behind or for sealing roofs.
The surface must be dry to slightly moist, and free from grease, oil, frost and tar. Loose components and protruding mortar residues must be removed before commencing work. Apply building waterproofing system primer coat (art. no. 0893 212 100) to prepare the surface. Sharp edges must be blunted, corner and transition areas must be rounded off by means of a chamfer with waterproof mortar (art. no. 0893 212 110). Depths > 5 mm should be evened out using waterproof mortar art. no. 0893 212 110. For proper application, the "Guidelines for planning seals of components in contact with the ground with plastic-modified bitumen-latex thick coatings" and the specifications in DIN 18533 must be observed! Ideally, single-component bitumen-latex thick coating should be stirred before application using a mixing paddle art. no. 0713 95 137 and an agitator, art. no. 0702 836. "Single-component bitumen-latex thick coating" must be applied in two layers. Both layers can be applied freshly on top of each other.
Chemical basis | Polystyrene- and plastic-filled bituminous emulsion |
Colour | Black |
Density | 0.7 g/cm³ |
Fully hardening/curing conditions | Depending on: coat thickness, substrate, temperature and humidity |
Conditions for ability to withstand rain | after skin formation, depending on the ambient humidity and temperature |
May be walked on in following conditions | once completely dry |
Further processing conditions | once completely dry |
Min. processing temperature | 5 °C |
Max. processing temperature | 35 °C |
Min. ambient processing temperature | 5 °C |
Min. surface processing temperature | 5 °C |
Max. surface processing temperature | 30 °C |
Max. temperature resistance | 70 °C |
Building material class | B2 - Normally inflammable |
Solvent-free | Yes |
Crack bridging | 3 mm |
Crack bridging conditions | for 6-mm layer thickness |
Application quantity in volume/area | 4.5 l/m² |
Application quantity conditions | with 4-mm layer thickness, complete system with two layers |
Contents | 30 l |
Container | Pail |
Weight of content | 21 kg |
Shelf life from production | 6 Month |
Conditions to maintain shelf life from production | cool and frost-free storage area, in sealed original container |
Required accessories | Trowel, art. no. 0695 943 ff, agitating paddle, art. no. 0713 95 ff |
Additional articles | Safety goggles, art. no. 0892102...; gloves, art. no. 0899435... |
Consumption/m² total system (2-layer construction) layer thickness for corresp. | |
4 mm | approx. 4.5 l/m² |
6 mm | approx. 6 l/m² |
1023/0432 | |
Adolf Würth GmbH & Co. KG, Reinhold Würth Straße 12-17, 74653 Künzelsau | |
Polymer-modified heavy-weight bitumen coating (PMB) for sealing construction components in contact with the ground | |
LE_0893212115_00_S_1C-heavy-weight bitumen coating | |
EN 158 14:2011 + A2:2014 | |
EN 13813:2002 | |
Essential characteristics | Performance |
Watertightness | Class W2A |
Crack bridging ability | Class CB2 |
Resistance to water | No discolouration of the water No detachment from the inlay |
Flexibility at low temperatures | No cracking |
Dimensional accuracy at high temperatures | No slipping or run-off |
Fire behaviour | Class E |
Compressive strength | Class C1 |
Permanence of watertightness and fire behaviour | Fulfilled |
Consumption: | |||
Information concerning the overall system! DIN 18533:2017-07 is authoritative for sealing. (Note the information concerning excess layer thickness in the "Processing" section.) | |||
Water impact class according to DIN 18533, tab. 1 | DLT [mm] | WLT [mm] | Consumption [l/m²] |
W1-E | 3,0 | 4,5 | At least 4.5 |
W2.1-E* | 4,0 | 5,8 | At least 5.8 |
W3-E* | 4,0 | 5,8 | At least 5.8 |
W4-E | 3,0 | 4,5 | At least 4.5 |
*Explanation of terms in the consumption table: W1-E: Soil moisture and non-pressurised water W2.1-E: Moderate influence of pressurised water (immersion depth = 3 m) W3-E: Non-pressurised water on ceilings covered with earth W4-E: Spray water and soil moisture on the wall base as well as capillary water in and under walls DLT: Minimum dry layer thickness WLT: Wet layer thickness | |||
If a 1C bitumen thick coating is applied as a scratch coating, excess layer thickness ordinarily required for the surface is unnecessary. *: The use of the material is based on DIN 18533. For use in the case of W2.2-E and W3-E, a special agreement is required in accordance with the test certificate |
Select RAL-colour code
!! NOTE: On-screen visualisation of the colour differs from real colour shade!!