Welcome to Würth Aerospace Solutions For trade customers only

1C liquid plastic Pro

1C liquid plastic PRO
LIQUPLA-1C-PRO-SET4KG

Art.-no. 0838892599
EAN 4058794221930

Prices for customers after login
1C liquid plastic Pro

Art.-no. 0838892599

Prices for customers after login
Quantity
PU
x 1 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

Single-component solvent-free liquid plastic for standard sealing for use in odour-sensitive areas
  • Solvent and isocyanate-free

  • Low-emission and easy-to-use

  • Thixotropic (the fluid becomes thinner as it is deformed/mixed)

  • Highly elastic

  • UV-resistant

  • Alkali-resistant

  • Resistant to hydrolysis

  • Rainproof after approx. 60 min

  • Low SD value (approx. 2 m)

  • Partial amounts can be removed so that remaining material does not need to be disposed of

  • High storage stability


Fire protection


  • BROOF (t1); BROOF (t2); BROOF (t3);BROOF (t4) to DIN EN 13501-5

  • Class E to DIN EN 13501-1
Proof of Performance
  • ETAG 005: ETA-19/0108. Guideline for the European Technical Approval for liquid roof seals

  • General test certificates from construction authorities for waterproofing buildings indoors and outdoors as well as for use on surfaces inclined at up to 90°.

  • DIN 18531 Waterproofing of roofs, balconies and walkways

  • DIN 18532 Waterproofing of concrete areas trafficable by vehicles

  • DIN 18533 Waterproofing of elements in contact with soil

  • DIN 18535 Waterproofing of tanks and pools
Base materialPre-treatmentPrimer
ScreedsGrinding, millingnot required
Glass*Cleaning of the surface with acetone cleaner; roughening of the surfacenot required
Hot bitumen paint*not requiredBitumen primer
WoodRemove paintnot required
Cold bitumen paint*not requiredBitumen primer
Plastic sheeting (EPDM)Cleaning of the surface with acetone cleanerBitumen primer
Plastic sheeting (EVA)Cleaning of the surface with acetone cleanerHard PVC primer
Plastic sheeting (PIB)*Cleaning of the surface with acetone cleaner; roughening of the surfaceBitumen primer
Plastic sheeting (PVC-P, NB)Cleaning of the surface with acetone cleaner; roughening of the surfaceSoft PVC primer
Plastic sheeting (TPO, FPO)Clean the surface with acetone cleaner; roughen the surfaceSpecial primer
Lightweight concreteClean the surface with acetone cleaner; roughen the surfacenot required
Powder-coated metals*Dry cleaning of the surface; roughening of the surfaceRust-Stop Quattro
Plaster/masonryremove paint if necessarynot required
Mortar, plastic-modifiedGrinding, millingnot required
Polymer bitumen membranes (PYE-E) mod. (SBS)not requiredBitumen primer
Polymer bitumen membranes (PYP) mod. (APP)*not requiredBitumen primer
PVC moulded parts, hardCleaning of the surface with acetone cleanerHard PVC primer
Steel, zinc-platedCleaning of the surface with acetone cleaner; roughening of the surfaceRust-Stop Quattro
Composite thermal insulation systems*not requirednot required
Other base materials on request
*Perform adhesion and compatibility tests
**Alternatively without roughening after adhesion test with CONNECTION primer
AluminiumClean the surface with acetone cleaner, roughen the surfaceRust Stop Quattro
Paints*Grinding, remove completelyDependent on substrate
AsphaltGrinding, millingBitumen primer
ConcreteGrinding, millingnot required
Stainless steelCleaning of the surface with acetone cleaner; roughening of the surfaceRust-Stop Quattro
Anodised aluminium**Cleaning of the surface with acetone cleaner; roughening of the surfaceRust-Stop Quattro
Air temperatureDew point temperatures in °C at a relative humidity of
12°C0,351,843,194,465,636,747,758,699,6010,4811,33
14°C2,203,765,106,407,588,679,7010,7111,6412,5513,36
15°C3,124,656,077,368,529,6310,7011,6912,6213,5214,42
16°C4,075,596,988,299,4710,6111,6812,6613,6314,5815,54
17°C5,006,487,929,1810,3911,4812,5413,5714,5015,3616,19
18°C5,907,438,8310,1211,3312,4413,4814,5615,4116,3117,25
19°C6,808,339,7511,0912,2613,3714,4915,4716,4017,3718,22
20°C7,739,3010,7212,0013,2214,4015,4816,4617,4418,3619,18
21°C8,6010,2211,5912,9214,2115,3616,4017,4418,4119,2720,19
22°C9,5411,1612,5213,8915,1916,2717,4118,4219,3920,2821,22
23°C10,4412,0213,4714,8716,0417,2918,3719,3720,3721,3422,23
24°C11,3412,9314,4415,7317,0618,2119,2220,3321,3722,3223,18
25°C12,2013,8315,3716,6917,9919,1120,2421,3522,2723,3024,22
26°C13,1514,8416,2617,6718,9020,0921,2922,3223,3224,3125,16
27°C14,0815,6817,2418,5719,8321,1122,2323,3124,3225,2226,10
28°C14,9616,6118,1419,3820,8622,0723,1824,2825,2526,2027,18
29°C15,8517,5819,0420,4821,8322,9724,2025,2326,2127,2628,18
30°C16,7918,4419,9621,4423,7123,9425,1126,1027,2128,1929,09
32°C18,6220,2821,9023,2624,6525,7927,0828,2429,2330,1631,17
34°C20,4222,1923,7725,1926,5427,8528,9430,0931,1932,1333,11
36°C22,2324,0825,5027,0028,4129,6530,8831,9733,0534,2335,06
38°C23,9725,7427,4428,8730,3131,6232,7833,9635,0136,0537,03
40°C25,7927,6629,2230,8132,1633,4834,6935,8636,9838,0539,11
45°C30,2932,1733,8635,3836,8538,2439,5440,7441,8742,9744,03
50°C34,7636,6338,4640,0941,5842,9944,3345,5546,7547,9048,98
The dew point table indicates at which surface temperatures condensation occurs. This is determined by the air temperature and relative humidity. Example: At an air temperature of 20°C and 55 % relative humidity, the dew point is at an object temperature of +10.7°C. The surface temperature should be 3°C above the dew point during application.
°C45 %50 %55 %60 %65 %70 %75 %80 %85 %90 %95 %
2°C-7.77-6.56-5.43-4.40-3.16-2.48-1.77-0.98-0.260,471,20
4°C-6.11-4.88-3.69-2.61-1.79-0.88-0.090,781,622,443,20
6°C-4.49-3.07-2.10-1.05-0.080,851,862,723,624,485,38
8°C-2.69-1.61-0.440,671,802,833,824,775,666,487,32
10°C-1.260,021,312,533,744,795,826,797,658,459,31
  • ETAG 005: ETA-19/0108. Guideline for the European Technical Approval for liquid roof seals

  • General test certificates from construction authorities for waterproofing buildings indoors and outdoors as well as for use on surfaces inclined at up to 90°.

  • DIN 18531 Waterproofing of roofs, balconies and walkways

  • DIN 18532 Waterproofing of concrete areas trafficable by vehicles

  • DIN 18533 Waterproofing of elements in contact with soil

  • DIN 18535 Waterproofing of tanks and pools

The usage instructions are recommendations based on the tests we have conducted and our experience; carry out your own tests before each application. Due to the large number of applications and storage and processing conditions, we do not assume any liability for a specific application result. Insofar as our free customer service provides technical information or acts as an advisory service, no responsibility is assumed by this service except where the advice or information given falls within the scope of our specified, contractually agreed service or the advisor was acting deliberately. We guarantee consistent quality of our products. We reserve the right to make technical changes and further develop products.



The DIN standards, regulations, technical regulations and recognised codes of practice applicable to the relevant trades must be observed, e.g. DIN 18195, DIN 18531, the technical regulations for metalwork in the roofing trade and the technical regulations for seals—the flat roof directive—issued by the ZVDH (German central association for the roofing trade). Würth accepts no liability relating to any application or implementation which is not specified by a standard, a technical regulation or the Würth work instructions, or which does not correspond to the recognised codes of practice.

Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area

For waterproofing used/unused roofing, balconies, components in contact with the ground, tanks and windows as well as for sealing foundations and bases in areas where they are in contact with the ground, wells and under foreign surfaces. In combination with a 110g/m² fleece inlay, a standard-compliant seal is created.



25 kg containers with lower viscosity for easier application on large surfaces.

Instructions

Stir material thoroughly with a stirrer before use. Before use, certain minimum adhesive strengths (concrete: 1.5 N/mm) must be proven on pre-treated test surfaces. The base material must be clean and dry (max. 6 % by weight, residual moisture) and free from grease and oil. Residual moisture on mineral base materials does not pose a problem. The possibility of rear moisture penetration must be eliminated. Cement residues must be removed. Substrate pre-treatment depends on the substrate. Observe the substrate table. The surface temperature must also be between 5°C and 35°C. The surface temperature must be 3°C above the dew point. Observe the dew point table below. Mask the edge areas of the surface to be sealed. Generously apply material using a roller or brush (2 kg/m2). Then insert the waterproofing membrane into the first layer bubble-free. Make sure that the parts are completely soaked. Then apply a further fresh layer of liquid plastic (1 kg/m2). Now check that no air bubbles are trapped inside the material. A minimum layer thickness of 2.1 mm must be ensured. With upturned edges, ensure a connection height above the surface of 15 cm. For waterproofing membrane overlaps, ensure that the sections overlap by 10 cm on extraneous material and by 5 cm with 1C liquid plastic Pro. For more information, please refer to the technical data sheet.

Chemical basis

Polyurethane

Colour

Grey

Density

1.5 g/cm³

Fully hardening/curing conditions

20°C

Suitable for further processing up to

24 h

Able to withstand rain after

60 min

Conditions for ability to withstand rain

at 20°C

Further processing conditions

without other measures

Min. processing temperature

5 °C

Max. processing temperature

35 °C

Max. temperature resistance

80 °C

Solvent-free

Yes

Crack bridging

5 mm

Crack bridging conditions

for 2-mm layer thickness

Application quantity in weight/area

3 kg/m²

Weight of content

4 kg

Shelf life from production

12 Month

Conditions to maintain shelf life from production

at 10°C to 30°C

Required accessory:
 
Product
Description
Quantity
PU
Price
/PU
1C flat roof seal fleece inlay, roll

FLCINLAY-FLEECE-15CMX50M

For processing the 1C flat roof seal Pro.
x 1 pcs
1C flat roof seal fleece inlay, roll

VLIEINLG-FLEECE-20CM

For processing the 1C flat roof seal Pro.
x 1 pcs
1C flat roof seal fleece inlay, roll

FLCINLAY-FLEECE-26,25CMX50M

For processing the 1C flat roof seal Pro.
x 1 pcs
1C flat roof seal fleece inlay, roll

FLCINLAY-FLEECE-35CMX50M

For processing the 1C flat roof seal Pro.
x 1 pcs
1C flat roof seal fleece inlay, roll

FLCINLAY-FLEECE-52,5CMX50M

For processing the 1C flat roof seal Pro.
x 1 pcs
1C flat roof seal fleece inlay, roll

FLCINLAY-FLEECE-70CM

For processing the 1C flat roof seal Pro.
x 1 pcs
1C flat roof seal fleece inlay, corner

FLCINLAY-FLEECE-INSIDECORNER-15CMX15CM

For processing the 1C flat roof seal Pro.
x 20 pcs
1C flat roof seal fleece inlay, corner

FLCINLAY-FLEECE-EXTERNALCORNER 16CMX16CM

For processing the 1C flat roof seal Pro.
x 20 pcs
1C flat roof seal fleece inlay, pipe

FLCINLAY-FLEECE-DUCT-80MM

For processing the 1C flat roof seal Pro.
x 10 pcs
1C flat roof seal fleece inlay, pipe

FLCINLAY-FLEECE-DUCT-110MM

For processing the 1C flat roof seal Pro.
x 10 pcs
1C flat roof seal fleece inlay, pipe

FLCINLAY-FLEECE-DUCT-135MM

For processing the 1C flat roof seal Pro.
x 10 pcs
The packaging unit defines the number of articles in one packaging. In the catalog segment you can choose from different packaging units if a pop-up menu is displayed.

Just leave the field empty if you don't know the packaging unit when directly entering the article number in the shopping basket or when importing with Easy-/VarioScan. The packaging unit will be determined automatically.
The article number is made up of the following: VVVVAAABBB
VVVV = 4 digits for prefix number (please note that the first digit is currently always 0)
AAA = 3 digits for dimension part 1
BBB = 3 digits for dimension part 2

Example article number structures:
Example 1: Screw with dimensions of 4x10 mm:
VVVVAAABBB
00574 10 (2 spaces between the 4 and the 10)

Example 2: Screw with dimensions of 10x20 mm:
VVVVAAABBB
005710 20 (1 space between the 10 and the 20)

Example 3: Flat washer with an internal diameter of 6 mm:
VVVVAAABBB
04076
Price per packaging unit (PU):
The displayed price is always in line with the displayed packaging, if the PU is 250 the price for 250 units, if the PU is 300 the price for 300 units.

Price with price key representation (PSL):
The price always applies to a quantity ruled through the price key:
Price for 1 unit
Price for 100 units
Price for 1000 units
The quantity shows the number of pieces or units of measure contained in the order or delivery for the respective article.
In contrast to sales packaging and secondary packaging, the disposal costs for chemical-technical products are shown separately. The breakdown of the individual costs can be found on the relevant products and also in the shopping cart, as well as in our General Terms and Conditions (GTC).
Additional accessory:
 
Product
Description
Quantity
PU
Price
/PU
Small radiator roller Professional

RADROLL-GIRMES-W100MM

Hard-wearing cover in high-quality polyamide
x 10 pcs
Radiator paint brush DW light For dispersions and wall paints

RADBRSH-DW-LGHT-SZ50

High-quality radiator paint brush with light bristles for a uniform surface finish due to fine fibre tips
Work scissors

WRKSHRS-L250MM

Robust, high-quality, rust-proof scissors for professional applications
Stirring rod

STIRR-F.PNT-450X35MM

For stirring and mixing
x 5 pcs
Soft PVC 1C liquid plastic primer

PRIM-LIQUIDPLASTIC-PVC-1LTR

Solvent-based 1-component primer for PVC substrates
x 1 pcs
Nitrile chemical protective glove With cotton velour finish inside

PROTGLOV-CHEM-NTR-330MM-SZ10

x 6 pcs
Cleaning cloth, textile

CLNRAG-TEXTILE-34X37CM-250PCS

For picking up coarse dirt, oils, greases, coolants and solvents
x 1 pcs
Crepe masking tape

MASKTPE-CRP-38MMX50M

General masking tasks in the vehicle and painting fields, for smooth and painted surfaces
x 8 pcs
The packaging unit defines the number of articles in one packaging. In the catalog segment you can choose from different packaging units if a pop-up menu is displayed.

Just leave the field empty if you don't know the packaging unit when directly entering the article number in the shopping basket or when importing with Easy-/VarioScan. The packaging unit will be determined automatically.
The article number is made up of the following: VVVVAAABBB
VVVV = 4 digits for prefix number (please note that the first digit is currently always 0)
AAA = 3 digits for dimension part 1
BBB = 3 digits for dimension part 2

Example article number structures:
Example 1: Screw with dimensions of 4x10 mm:
VVVVAAABBB
00574 10 (2 spaces between the 4 and the 10)

Example 2: Screw with dimensions of 10x20 mm:
VVVVAAABBB
005710 20 (1 space between the 10 and the 20)

Example 3: Flat washer with an internal diameter of 6 mm:
VVVVAAABBB
04076
Price per packaging unit (PU):
The displayed price is always in line with the displayed packaging, if the PU is 250 the price for 250 units, if the PU is 300 the price for 300 units.

Price with price key representation (PSL):
The price always applies to a quantity ruled through the price key:
Price for 1 unit
Price for 100 units
Price for 1000 units
The quantity shows the number of pieces or units of measure contained in the order or delivery for the respective article.
In contrast to sales packaging and secondary packaging, the disposal costs for chemical-technical products are shown separately. The breakdown of the individual costs can be found on the relevant products and also in the shopping cart, as well as in our General Terms and Conditions (GTC).

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information