Adapter for AMO-Therm Mini stand-off installation system
ADAPT-(AMOTHERM-MINI)-16X59-M8/M10+INRT
Art.-no. 5913115016
EAN 4062856540884
Register now and access more than 125,000 products
- The AMO-Therm Mini stand-off installation system enables anchor-less fastening of light to medium loads in insulated façades, while maintaining thermal break.
- The screw is anchored through the insulation directly into the masonry and ensures secure and stable fastening.
- A single screw length covers insulation thicknesses from 60 mm to 200 mm, and therefore the length of thread engagement can be easily adjusted depending on the insulation thickness.
- Available separately is an adapter with a formed M8/M10 internal thread that consists of two half shells that can be clipped together over the screw shank.
- For additional safety, it is recommended that the adapter is pressed together at the front and rear using combination pliers.
- The adapter does not sit tightly around the screw head, which allows both elements to be rotated separately.
- Use the adapter to connect ASSY-D screws.
- Down pipe mounting with M10x45 mm threaded stud in A2 stainless steel, including collar and sealing washer.
- Thermal-bridge-free mounting in masonry ensures efficient insulation.
This adapter can only be used in conjunction with the screw for the AMO-Therm Mini stand-off installation system. A special drill bit for concrete and another for masonry are included in the set. Please observe the recommendations mentioned under Accessories.
Spacer installation system AMO®-Therm Mini: Downpipe attachment in masonry
Spacer installation system AMO®-Therm Mini: Downpipe attachment in concrete
Mount the countersink on the drill bit
Observe the marking
Drilling core hole and countersink in one step. The generally required drilling depth of 288 mm is achieved when the end of the countersink is flush with the surface of the wall plaster
Remove drill cuttings from drill hole
The adapter offers an M8/M10 combination connection.
The two half-shells are clipped together centrally over the screw shaft using combination pliers. As a precaution, use the combination pliers to press the adapter together at the top and bottom. The adapter does not sit tightly around the screw head, both elements can be rotated separately
The drive is reached with a 70-mm bit, the screw is screwed into the base material flush with the surface (plaster or insulation). The adapter is then adjusted with a 1-mm protrusion. As soon as the outer bars of the adapter are able to engage in the insulation, the adapter no longer turns with the rest of the unit
Fill the ring gap with window and façade sealant
Installation of downpipe clamp: Screw threaded rod M10 flush into the adapter
Remove the adhesive film from the sealing washer and push over the threaded rod flush to the surface with the adhesive coating facing up
Screw on the collar flush
Screw on the downpipe clamp
Installing M10/M8: The attachment is fastened with a suitable screw
Screw in screw until flush
The supplied insert is screwed into the M10 thread, thus creating a mounting option for an ASSY-D® screw ∅ 4-5
Screw in screw until flush
Datasheets(X)
For attaching light to medium loads (post boxes, lamps, surveillance cameras, or guttering pipes [non-structural system based on a redundant design]) in insulated façades with or without plaster.
Fill the ring gap between the insulation and the adapter with a suitable sealant. We recommend Window Window and façade sealant art. no. 0892 320 010.
![]() | |
Outer diameter | 16 mm |
Length | 59 mm |
Female thread | 8 mm |
Female thread 2 | 10 mm |
Material | PA GF - Polyamide glass fiber reinforced |
Nominal drill-bit diameter (d 0) | 10 mm |
Min. drill hole depth | 288 mm |
Nominal drill hole diameter | 10 mm |
Spot-facer diameter | 16 mm |
Screw diameter | 11.5 mm |
Screw length | 252 mm |
Max. insulation thickness | 200 mm |
| Legend of AMO-Therm Mini installation situation | |
| hmin | Minimum component thickness |
| dmw | Bore diameter, masonry |
| db | Bore diameter, concrete |
| dp | Bore diameter, plaster |
| tD | Min. bore depth (total) |
| hnom | Embedment depth |
| e | Thickness of non-load-bearing layer (ttol + tinsulation + ü) |
| ü | Overhang ≥ 1 mm |
| ttol | Thickness of old plaster and/or adhesive |
| Transverse tensile load in conjunction with M8 and M10 connection elements or with ASSY D 5 plug screw* | ||
| Transverse tensile capacity | Vrec. | |
| [kN] | ||
| All insulation thicknesses and surfaces | 0,2 | |
| Installation parameters of fasteners in the adapter | ||
| Type of fastener | Max. tightening torque Mrec. [Nm] | Length of thread engagement [mm] |
| M8 | 2,5 | 20-24 |
| M10 | 3,5 | 8-12 |
| ASSY-D 4* | 0,7 | 18-24 |
| ASSY-D 5* | 1 | |
| * with insert in adapter | ||
| Recommended loads | |||
| Centric tensile load in conjunction with M8 and M10 fasteners in different surfaces | Centric tensile load in conjunction with ASSY-D plug screw* 4 to 5 mm in all surfaces | ||
| Tensile capacity | Nrec. | Tensile capacity | Nrec. |
| Base | [kN] | [kN] | |
| Concrete C20/25 | 0,8 | All surfaces | 0,25 |
| Solid brick MZ 36 | 0,8 | ||
| Solid sand-lime brick KSV 12 | 0,8 | ||
| Vertically perforated brick HLZ 12 | 0,3 | ||
| Hollow sand-lime brick KSL 12 | 0,8 | ||
| Aerated concrete PB 4 | 0,6 | ||
| Installation parameters | |
| Nominal bore diameter in masonry dmw | 10 mm |
| Nominal bore diameter in concrete db | 7/16 inch |
| Min. borehole depth (base + insulation + plaster) tD | 288 mm |
| Insulation thickness (mm) | Embedment depth in surface hnom (mm) |
| 60 | 218 |
| 80 | 198 |
| 100 | 178 |
| 120 | 158 |
| 140 | 138 |
| 160 | 118 |
| 180 | 98 |
| 200 | 78 |