Welcome to Würth Aerospace Solutions For trade customers only

Concrete screw W-BS/S type ST-6 as a stair bolt With connecting thread

Concrete screw W-BS steel zinc plated type ST
ANC-(W-BS/ST)-(A2K)-WS10-M8X16-20-6X55

Art.-no. 5929186020
EAN 4046777685848

Prices for customers after login
Concrete screw W-BS/S type ST-6 as a stair bolt With connecting thread

Art.-no. 5929186020

Prices for customers after login
Quantity
PU
x 100 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

Ideal for fastening pipe clamps or spacer sleeves, zinc-plated steel
  • For anchorage in concrete and masonry

  • Extremely flexible application thanks to up to three effective anchorage depths

  • With metric connection thread for direct fastening of e.g. pipe clamps

  • High loads

  • Very low spacing and edge distances thanks to very low expansion effect

  • Very fast and easy installation, particularly overhead, and immediate load-bearing capacity

  • Fastening can be adjusted up to two times after installation (please refer to the installation instructions)
Proof of Performance

European Technical Assessment ETA-16/0043 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static and quasi-static action (dia. 6)

  • Seismic action, performance category C1 (dia. 6, tension load only)

  • Fire resistance R30, R60, R90, R120


European Technical Assessment ETA-23/0196 for anchorage in masonry


  • Static and quasi-static action (dia. 6)

  • Fire resistance R30, R60, R90, R120 (dia. 6)


European Technical Assessment ETA-16/0128 for anchors in a redundant non-structural system:


  • Cracked and uncracked concrete, (dia. 6)

  • Hollow-core prestressed concrete ceilings C30/37-C50/60, (dia. 6)

  • Fire resistance R30, R60, R90, R120


Fire resistance rating when exposed to fire according to the standard temperature time curve in masonry (Mz, KSL, KS) - expert report no 2101/173/18 - 2018

Notice

When installing with a tangential impact driver, the recommended maximum nominal torque must be observed. The maximum installation torque specified must be observed when installing the fixtures. When used in masonry, the stone-specific installation data according to ETA-23/0196 must be observed.

Application area

Adjustment - subsequent aligning possible

European Technical Assessment ETA-16/0043 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static and quasi-static action (dia. 6)

  • Seismic action, performance category C1 (dia. 6, tension load only)

  • Fire resistance R30, R60, R90, R120


European Technical Assessment ETA-23/0196 for anchorage in masonry


  • Static and quasi-static action (dia. 6)

  • Fire resistance R30, R60, R90, R120 (dia. 6)


European Technical Assessment ETA-16/0128 for anchors in a redundant non-structural system:


  • Cracked and uncracked concrete, (dia. 6)

  • Hollow-core prestressed concrete ceilings C30/37-C50/60, (dia. 6)

  • Fire resistance R30, R60, R90, R120


Fire resistance rating when exposed to fire according to the standard temperature time curve in masonry (Mz, KSL, KS) - expert report no 2101/173/18 - 2018

Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Anchorages in concrete, individual fixing point with approval (dia. 6)


In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete)



Anchors in a redundant non-structural system in concrete, with approval:


  • In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete, (dia. 6))

  • In hollow-core prestressed concrete ceilings C30/37-C50/60, (dia. 6)


Anchorages in masonry with approval (dia. 6):


  • In solid calcium silicate block and perforated block

  • In solid block masonry brick


With metric connection thread, therefore a highly efficient fastening solution in concrete for numerous applications involving technical building equipment such as in sanitary, air-conditioning and electrical installations or for fixtures that need to be removable



Ideal for fastening medium loads in concrete and light to medium loads in masonry:


  • E.g. for fastening pipes, ventilation ducts, cable clamps, suspensions with threaded rods, mounting rails, brackets, metal profiles, brackets for façade or ceiling substructures in pre-positioned installation

  • Fastenings subject to seismic activity in earthquake-prone areas (only concrete)

  • Fastenings subject to exposure to fire


W-BS/S (galvanised steel) may only be used in dry indoor room conditions



For use in concrete < C20/25 and pressure-resistant natural stone (without approval)

Anchor size

6 mm

Anchor length (l)

55 mm

Connection thread

M8 x 16

Attachment height (t fix 1)

20 mm

Attachment height (t fix 2)

15 mm

Attachment height (t fix 3)

0 mm

Thread diameter

7.5 mm

Nominal drill-bit diameter (d 0)

6 mm

Drill hole depth (h 1.1)

40 mm

Drill hole depth (h 1.2)

45 mm

Drill hole depth (h 1.3)

60 mm

Embedding depth (h nom1)

35 mm

Embedding depth (h nom2)

40 mm

Embedding depth (h nom3)

55 mm

External drive

WS10

Material

Steel

Surface

Zinc plated

Through-hole in the component to be connected (d f)

8 mm

Head type

With connection thread (metric)

Type description

W-BS type ST

Performance data in concrete - fixing point according to ETA-16/0043
Anchor size [mm]6
C2
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-16/0043
Length of anchor in drilled holehnom [mm]4055
Admissible centric tension load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
Nperm. [kN] = C20/252)1,01,9
Compressive zone
(non-cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
1,94,3
Admissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252), c ≥ 10 hef)
Vperm. [kN] = C20/252)3,03,3
Compressive zone
(non-cracked concrete C20/252), c ≥ 10 hef)
3,33,3
Permissible bending moment Madm [Nm]4,8
Admissible load under seismic activity performance categories C1 and C2 see European Technical Assessment ETA-16/0043C1xx
Performance data in concrete - anchors in a redundant non-structural system according to ETA-16/0128
Anchor size [mm]6
Length of anchor in drilled holehnom [mm]3555
Anchors in concrete in a non-structural system based on a redundant design3)Nperm. [kN] ≥ C20/250,63.64)
Admissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252), c ≥ 10 hef)
Vperm. [kN] = C20/252)2,03,3
Compressive zone
(non-cracked concrete C20/252), c ≥ 10 hef)
2,83,3
Permissible bending moment Madm [Nm]4,8
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-16/0128
Performance data in hollow-core prestressed concrete ceilings according to ETA-16/0128
Anchor size [mm]6
Mirror thickness [mm]≥ 25≥ 30≥ 35
Anchors in a redundant non-structural system in hollow-core prestressed concrete ceilings5)Fperm. [kN] 0,40,81,2
Installation parameters in concrete
Anchor size [mm] 6
Diameter of cutting edgesdcut ≤ [mm]6,40
Drill hole depthh1 ≥ [mm]404560
Through hole in the component being connecteddf ≤ [mm]8
Width across flats[mm]WS10
Screw-head heighthh [mm]20
Connecting thread M8 x 16 mm
Max. rated torque of tangential impact screwdriverTimp,max [Nm]160
Installation torqueTinst ≤ [Nm]10
Nominal length of thread engagementhnom [mm]351)4055
Minimum axis distance smin [mm]3540
Axis distancescr,N [mm]8193132
Minimum edge distancecmin [mm]3540
Edge distanceccr,N [mm]40,546,566
Minimum member thicknesshmin [mm]80
Nominal drill diameterd0 [mm]6
Installation parameters in pre-loaded hollow ceiling panels
Anchor size [mm] 6
Through hole in the component being connecteddf ≤ [mm]8
Minimum axis distance smin [mm]100
Minimum edge distancecmin [mm]100
Minimum spacing between the groups of anchorsamin [mm]100
Spacing between cavity axeslc ≥ [mm]100
Spacing between tensioning strandslp ≥ [mm]100
Spacing between tensioning strands and drilled holeap ≥ [mm]50
Nominal drill diameterd0 [mm]6
Performance data of an individual anchor in solid and perforated block masonry according to ETA-23/0196
Anchor sizeNominal length of thread engagementAdmissible tensile loadAdmissible shear loadMin. edge distanceMin. spacingDistance from jointsMax. torque for manual installationMax. torque for installation with drill/driverInstallation using tangential impact driver
[mm][mm][kN][kN][mm][mm][mm][mm][Nm][Nm][Nm]
Solid calcium silicate block KS NF in accordance with EN 771-2:2015-11
KS 20 - 2.0 - NF - 240 x 115 x 71 mm, stone raw density ρ ≥ 2.0 kg/dm3, stone compressive strength fmean = 26 N/mm2, minimum wall thickness hmin = 240 mm
Silka XL solid calcium silicate block KS 12DF in accordance with DIN EN 771-2:2015-11
KS- R (P) - 2.0 - 12DF - 498 x 175 x 148 mm, stone raw density ρ ≥ 1.8 kg/dm3, stone compressive strength fmean = 14 N/mm2, minimum wall thickness hmin = 175 mm
6350,660,91808040801010
6551,172,378080408010 185
Hollow calcium silicate block KS L, 3DF in accordance with DIN EN 771-2:2015-11
SWKV KSL 12 - 1.6 - 3DF - 240 x 175 x 113 mm, stone raw density ρ ≥ 1.5 kg/dm3, stone compressive strength fmean = 17 N/mm2, minimum wall thickness hmin = 175 mm
6350,310,46588035581110100
6550,310,465880355811 100
Masonry brick Mz in accordance with DIN EN 771-1:2015-11
Mz 20 - 2.0 - NF - 240 x 115 x 75 mm, stone raw density ρ ≥ 2.1 kg/dm3, stone compressive strength fmean = 21 N/mm2, minimum wall thickness hmin = 240 mm
6350,460,68080358039
6550,460,68080358039
hnomNadmVadmcminSmin, || = Smin,cj ⊥ ≥cj ||TinstTinstTimp,max
6350,890,94808035801110185
6551,40,948080358011 185
General installation parameters in masonry:
Anchor sizeDiameter6
Through hole in the fixturedf[mm]8
Nominal length of thread engagementhnomhnom1hnom2
[mm]3555
Nominal drill diameterd0[mm]6
Diameter of cutting edgesdcut[mm]6,4
Drill hole depthh0[mm]5575
Additional accessory:
 
Product
Description
Quantity
PU
Price
/PU
Blow-out bulb for drill hole cleaning

BLWOUTBULB-F.CLN

For cleaning drill holes with a smaller diameter
The packaging unit defines the number of articles in one packaging. In the catalog segment you can choose from different packaging units if a pop-up menu is displayed.

Just leave the field empty if you don't know the packaging unit when directly entering the article number in the shopping basket or when importing with Easy-/VarioScan. The packaging unit will be determined automatically.
The article number is made up of the following: VVVVAAABBB
VVVV = 4 digits for prefix number (please note that the first digit is currently always 0)
AAA = 3 digits for dimension part 1
BBB = 3 digits for dimension part 2

Example article number structures:
Example 1: Screw with dimensions of 4x10 mm:
VVVVAAABBB
00574 10 (2 spaces between the 4 and the 10)

Example 2: Screw with dimensions of 10x20 mm:
VVVVAAABBB
005710 20 (1 space between the 10 and the 20)

Example 3: Flat washer with an internal diameter of 6 mm:
VVVVAAABBB
04076
Price per packaging unit (PU):
The displayed price is always in line with the displayed packaging, if the PU is 250 the price for 250 units, if the PU is 300 the price for 300 units.

Price with price key representation (PSL):
The price always applies to a quantity ruled through the price key:
Price for 1 unit
Price for 100 units
Price for 1000 units
The quantity shows the number of pieces or units of measure contained in the order or delivery for the respective article.
In contrast to sales packaging and secondary packaging, the disposal costs for chemical-technical products are shown separately. The breakdown of the individual costs can be found on the relevant products and also in the shopping cart, as well as in our General Terms and Conditions (GTC).

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information