Concrete screw with hexagon head W-BS/S

Concrete screw W-BS steel zinc plated type S
ANC-(W-BS/S)-(A2K)-WS13-10-15-6X50

Art.-no. 5929126015
EAN 4046777684889

Prices for customers after login
Concrete screw with hexagon head W-BS/S

Art.-no. 5929126015

Prices for customers after login
Quantity
PU
x 100 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

Highest loads and efficient installation. Ideal for fastening metal structures, zinc-plated steel
  • For anchorage in concrete and masonry

  • Extremely flexible application thanks to up to three effective anchorage depths (size 6-14)

  • Fastening can be adjusted up to two times after installation (size 6-14), for example in order to align railings or anchor plates (please refer to the installation instructions)

  • Very high loads

  • Very low spacing and edge distances thanks to very low expansion effect

  • Very fast and easy installation and immediate load-bearing capacity
Proof of Performance

European Technical Assessment ETA-16/0043 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static and quasi-static action (dia. 6-14)

  • Seismic action, performance category C1 (dia. 6-14) and C2 (dia. 8-14)

  • Fire resistance R30, R60, R90, R120


European Technical Assessment ETA-23/0196 for anchorage in masonry


  • Static and quasi-static action (dia. 5-10)

  • Fire resistance R30, R60, R90, R120 (dia. 5-6)


European Technical Assessment ETA-16/0128 for anchors in a redundant non-structural system:


  • Cracked and uncracked concrete, (dia. 5 and dia. 6)

  • Hollow-core prestressed concrete ceilings C30/37-C50/60, (dia. 6)

  • Fire resistance R30, R60, R90, R120


DIBt National technical approval/general type approval Z-21.8-2090 for temporary anchorage in concrete (dia. 10-14, type S hexagon head)


  • In reinforced and non-reinforced and cracked and uncracked concrete C20/25 to C50/60

  • Use in fresh concrete

  • Multiple use


DIBt National technical approval/general type approval Z-21.1-2075 as bonded screw anchor for anchorage in concrete (dia. 10-14, type S hexagon head)


  • Use in combination with WIT-BS injectable mortar as WIT-BS bonded screw anchor

  • In reinforced and non-reinforced and cracked and uncracked concrete C20/25 to C50/60


Tensile capacity in hollow-core concrete ceilings, (dia. 6-10) - expert report no. 21641 - 2016



Fire resistance rating when exposed to fire according to the standard temperature time curve in masonry (Mz, KSL, KS) and reinforced concrete, (dia. 5 and dia. 6) - expert report no. 2101/173/18 - 2018

Notice

From size 8, we recommend the use of a suitable tangential impact driver for installation. The recommended maximum nominal torque must be observed.


When used in masonry, the stone-specific installation data according to ETA-23/0196 must be observed.

Application area

Steel supports

Brackets

Adjustment - subsequent aligning possible.

Create the drill hole

Clean the drill hole

Place screw

Screw in the screw

Considered installed when the head is close fitting

Screw out the screw max. 2x each by max. 10 mm. Underlay. Screw in

Considered installed when the head is close fitting. Lining max. 10 mm. The required embedment depth must be maintained as a minimum

Locate the tensioning strand

Mark the tensioning strand and locate the next one

Mark the tensioning strands. Specify the drilling range

Create the drill hole. Observe spacing

Clean the drill hole

Screw in the screw

Considered installed when the head is close fitting. Observe the embedment depth/mirror thickness

European Technical Assessment ETA-16/0043 for individual fixing point, option 1, cracked and uncracked concrete:


  • Static and quasi-static action (dia. 6-14)

  • Seismic action, performance category C1 (dia. 6-14) and C2 (dia. 8-14)

  • Fire resistance R30, R60, R90, R120


European Technical Assessment ETA-23/0196 for anchorage in masonry


  • Static and quasi-static action (dia. 5-10)

  • Fire resistance R30, R60, R90, R120 (dia. 5-6)


European Technical Assessment ETA-16/0128 for anchors in a redundant non-structural system:


  • Cracked and uncracked concrete, (dia. 5 and dia. 6)

  • Hollow-core prestressed concrete ceilings C30/37-C50/60, (dia. 6)

  • Fire resistance R30, R60, R90, R120


DIBt National technical approval/general type approval Z-21.8-2090 for temporary anchorage in concrete (dia. 10-14, type S hexagon head)


  • In reinforced and non-reinforced and cracked and uncracked concrete C20/25 to C50/60

  • Use in fresh concrete

  • Multiple use


DIBt National technical approval/general type approval Z-21.1-2075 as bonded screw anchor for anchorage in concrete (dia. 10-14, type S hexagon head)


  • Use in combination with WIT-BS injectable mortar as WIT-BS bonded screw anchor

  • In reinforced and non-reinforced and cracked and uncracked concrete C20/25 to C50/60


Tensile capacity in hollow-core concrete ceilings, (dia. 6-10) - expert report no. 21641 - 2016



Fire resistance rating when exposed to fire according to the standard temperature time curve in masonry (Mz, KSL, KS) and reinforced concrete, (dia. 5 and dia. 6) - expert report no. 2101/173/18 - 2018

Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Anchorages in concrete, individual fixing point with approval (dia. 6-14):


In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete)



Anchors in a redundant non-structural system in concrete, with approval:


  • In normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete), (dia. 5 and dia. 6)

  • In hollow-core prestressed concrete ceilings C30/37-C50/60, (dia. 6)


Anchorages in masonry with approval (dia. 5-10):


  • In solid calcium silicate block and perforated block

  • In solid block masonry brick


Suitable for fastening medium to heavy loads in concrete and light to medium loads in masonry:


  • Fastening of e.g. metal structures, metal profiles, brackets, base plates, supports, cable trays, pipes, railings, construction site equipment etc. in in-place installation

  • Fastenings subject to seismic activity in earthquake-prone areas (only concrete)

  • Fastenings subject to exposure to fire


W-BS/S (galvanised steel) may only be used in dry indoor room conditions



Temporary fastening of construction site equipment may be carried out indoors and outdoors



For use in concrete < C20/25 and pressure-resistant natural stone (without approval)

Anchor size

6 mm

Anchor length (l)

50 mm

Attachment height (t fix 1)

15 mm

Attachment height (t fix 2)

10 mm

Thread diameter

7.5 mm

Nominal drill-bit diameter (d 0)

6 mm

Drill hole depth (h 1.1)

40 mm

Drill hole depth (h 1.2)

45 mm

Embedding depth (h nom1)

35 mm

Embedding depth (h nom2)

40 mm

External drive

WS13

Material

Steel

Surface

Zinc plated

Washer diameter

15 mm

Through-hole in the component to be connected (d f)

8 mm

Head type

Hexagon head

Type description

W-BS type S

Performance data in concrete - individual fixing point according to ETA-16/0043
Anchor size [mm]68101214
Admissible load under seismic activity performance categories C1 and C2 see European Technical Assessment ETA-16/0043C1xx xx x x x
C2 x x x x
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-16/0043
Nominal length of thread engagementhnom [mm]4055455565557585658510075100115
Admissible centric tension load1) on an individual anchor without the influence of the edge distanceTensile zone
(cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
Nadm [kN] = C20/252)1,01,92,44,35,74,38,09,65,79,412,37,612,015,1
Compressive zone
(uncracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
1,94,33,65,77,65,79,511,97,613,217,210,616,921,2
Permissible shear load1) on an individual anchor without the influence of the edge distanceTensile zone
(cracked concrete C20/252), c ≥ 10 hef)
Vadm [kN] = C20/252)3,03,33,64,86,44,815,916,26,118,820,07,624,126,7
Compressive zone
(uncracked concrete C20/252), c ≥ 10 hef)
3,33,35,06,88,16,816,216,28,520,020,010,626,726,7
Permissible bending moment Madm [Nm]4,812,426,753,888,1
Performance data in concrete - anchors in a redundant non-structural system according to ETA-16/0128
Anchor size [mm]56
Nominal length of thread engagementhnom [mm]353555
Anchors in concrete in a non-structural system based on a redundant design3)Nadm [kN] ≥ C20/250,60,63.64)
Permissible shear load1) on an individual anchor without the influence of the edge distanceTensile zone
(cracked concrete C20/252), c ≥ 10 hef)
Vadm [kN] = C20/252)2,02,03,3
Compressive zone
(uncracked concrete C20/252), c ≥ 10 hef)
2,12,83,3
Permissible bending moment Madm [Nm]2,54,8
Admissible load when exposed to fire (R30, R60, R90, R120), see European Technical Assessment ETA-16/0128
Performance data in hollow-core prestressed concrete ceilings according to ETA-16/0128
Anchor size [mm]6
Mirror thickness [mm]≥ 25≥ 30≥ 35
Anchors in a redundant non-structural system in hollow-core prestressed concrete ceilings5)Fadm [kN]0,40,81,2
Installation parameters in concrete
Anchor size [mm]568101214
Through hole in the component being connecteddf ≤ [mm]7812141618
Width across flats[mm]AF10AF13AF13AF15AF17AF21
Washer diameterdw [mm]12,51516202328
Screw-head heighthn [mm]569101012,5
Max. rated torque of tangential impact screwdriverTimp,max [Nm]110160300400650650
Nominal length of thread engagementhnom [mm]351)351)4055455565557585658510075100115
Minimum axis distance smin [mm]35354040505050705070
Axis distancescr,N [mm]818193132105129156129180204150201240174237276
Minimum edge distancecmin [mm]35354040505050705070
Edge distanceccr,N [mm]40,540,546,56652,564,57864,59010275100,512087118,5138
Minimum member thicknesshmin [mm]80808080901028010112087119138
Nominal drill ∅d0 [mm]568101214
∅ of cutting edgesdcut ≤ [mm]5,406,408,4510,4512,5014,50
Drill hole depthh1 ≥ [mm]40404560556575658595759511085110125
Installation parameters in pre-loaded hollow ceiling panels
Anchor size [mm]6
Spacing between tensioning strands and drilled hole ap ≥ [mm]50
Nominal drill ∅d0 [mm]6
Through hole in the component being connecteddf ≤ [mm]8
Minimum axis distance smin [mm]100
Minimum edge distancecmin [mm]100
Minimum spacing between the groups of anchorsamin [mm]100
Spacing between cavity axes lc ≥ [mm]100
Spacing between tensioning strands lp ≥ [mm]100
Performance data of an individual anchor in solid and perforated block masonry according to ETA-23/0196
Anchor sizeNominal length of thread engagementAdmissible tensile loadAdmissible shear loadMin. edge distanceMin. spacingDistance from jointsMax. torque for manual installationMax. torque for installation with drill/driverInstallation using tangential impact driver
Solid calcium silicate block KS NF in accordance with EN 771-2:2015-11
KS 20 - 2.0 - NF - 240 x 115 x 71 mm, stone raw density ρ ≥ 2.0 kg/dm3, stone compressive strength fmean = 26 N/mm2,
minimum wall thickness hmin = 240 mm
Silka XL solid calcium silicate block KS 12DF in accordance with DIN EN 771-2:2015-11
KS- R (P) - 2.0 - 12DF - 498 x 175 x 148 mm, stone raw density ρ ≥ 1.8 kg/dm3, stone compressive strength fmean = 14 N/mm2,
minimum wall thickness hmin = 175 mm
Hollow calcium silicate block KS L, 3DF in accordance with DIN EN 771-2:2015-11
SWKV KSL 12 - 1.6 - 3DF - 240 x 175 x 113 mm, stone raw density ρ ≥ 1.5 kg/dm3, stone compressive strength fmean = 17 N/mm2, minimum wall thickness hmin = 175 mm
Masonry brick Mz in accordance with DIN EN 771-1:2015-11
Mz 20 - 2.0 - NF - 240 x 115 x 75 mm, stone raw density ρ ≥ 2.1 kg/dm3, stone compressive strength fmean = 21 N/mm2, minimum wall thickness hmin = 240 mm
Lightweight concrete solid block Vbl in accordance with DIN EN 771-3:2015-11
Vbl 4 - 1.0 - 2DF - 240 x 115 x 113 mm, stone raw density ρ ≥ 1.5 kg/dm3, stone compressive strength fmean = 4 N/mm2, minimum wall thickness hmin = 240 mm
5350,660,91808040806
6350,660,91808040801010
6551,172,378080408010 185
8451,80,918080408025 300
8651,82,148080408025 300
10551,831,698080408045 300
10751,912,448080408045 300
5350,310,465880355868100
6350,310,46588035581110100
6550,310,465880355811 100
8450,460,465880355827 200
8650,460,465880355827 200
10550,630,635880355837 200
10750,630,635880355846 200
5350,460,68080358024
6350,460,68080358039
6550,460,68080358039
8450,660,6808035801614
8650,660,6808035801614
10550,860,68080358023 185
10750,910,778080358023 185
8650,170,6680803580610
10750,370,9180803580514
hnomNadmVadmcminsmin, || = smin, ⊥cj ⊥cj ||TinstTinstTimp,max
[mm][mm][kN][kN][mm][mm][mm][mm][Nm][Nm][Nm]
53510,94808035806 185
6350,890,94808035801110185
6551,40,948080358011 185
8451,170,948080358027 300
8651,230,948080358023 300
10551,060,948080358034 300
10751,290,9480803580146 300
General installation parameters in masonry:
Anchor sizeDiameter56810
Nominal length of thread engagementhnomhnom1hnom1hnom2hnom1hnom2hnom1hnom2
[mm]35355545655575
Nominal drill diameterd0[mm]56810
Diameter of cutting edgesdcut[mm]5,46,48,4510,45
Drill hole depthh0[mm]55557565857595
Through hole in the fixturedf[mm]781214
Additional accessory:
 
Product
Description
Quantity
PU
Price
/PU
Blow-out bulb for drill hole cleaning

BLWOUTBULB-F.CLN

For cleaning drill holes with a smaller diameter
The packaging unit defines the number of articles in one packaging. In the catalog segment you can choose from different packaging units if a pop-up menu is displayed.

Just leave the field empty if you don't know the packaging unit when directly entering the article number in the shopping basket or when importing with Easy-/VarioScan. The packaging unit will be determined automatically.
The article number is made up of the following: VVVVAAABBB
VVVV = 4 digits for prefix number (please note that the first digit is currently always 0)
AAA = 3 digits for dimension part 1
BBB = 3 digits for dimension part 2

Example article number structures:
Example 1: Screw with dimensions of 4x10 mm:
VVVVAAABBB
00574 10 (2 spaces between the 4 and the 10)

Example 2: Screw with dimensions of 10x20 mm:
VVVVAAABBB
005710 20 (1 space between the 10 and the 20)

Example 3: Flat washer with an internal diameter of 6 mm:
VVVVAAABBB
04076
Price per packaging unit (PU):
The displayed price is always in line with the displayed packaging, if the PU is 250 the price for 250 units, if the PU is 300 the price for 300 units.

Price with price key representation (PSL):
The price always applies to a quantity ruled through the price key:
Price for 1 unit
Price for 100 units
Price for 1000 units
The quantity shows the number of pieces or units of measure contained in the order or delivery for the respective article.
In contrast to sales packaging and secondary packaging, the disposal costs for chemical-technical products are shown separately. The breakdown of the individual costs can be found on the relevant products and also in the shopping cart, as well as in our General Terms and Conditions (GTC).

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information