Female thread anchor with collar and metric thread for economical anchoring in concrete, zinc plated steel
  • Small drill hole depth

  • High load-bearing capacities

  • Visual setting check and hand protection when installing with the marking/spreading tool

  • Mechanical setting tool makes installation quicker and easier

  • Immediate load-bearing capacity — no waiting

  • Attached part can easily be removed at any time

  • W-ED/S has collar enabling anchor to be installed flush with the surface and preventing it slipping further into the drill hole (safer installation)

  • The attached part can be anchored with a fastening screw or a threaded rod

  • No installation torque required
Proof of Performance
  • ETA-02/0044 for individual fixing point, option 7, uncracked concrete

  • ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Notice

Drive-in anchor W-ED/A4 see [13.2]

Application area
Suspended ceilings

Drill the hole

Clean the drill hole

Knock in anchor until flush

Anchor with expander tool

Fit component, apply torque

  • ETA-02/0044 for individual fixing point, option 7, uncracked concrete

  • ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Product information

Datasheets(X)

Certificates/ Documents

 | 

 | 

Application area
  • Individual fixing point: Normal weight concrete C20/25 to C50/60 (uncracked concrete)

  • Anchors in a redundant non-structural system: Anchorage of non-load-bearing systems (cracked and uncracked concrete)

  • Suitable for fastening threaded rods, metal structures, metal profiles, lattices, cable conduits, pipes, mounting rails etc.

  • For use in concrete < C20/25 and pressure-resistant natural stone (without approval)

  • W-ED/S, W-ED/S-BND and W-ED M5 may only be used in dry indoor conditions

Anchor diameter

8 mm

Anchor length (L H)

25 mm

Min./max. required screw-in depth

8-12 mm

Material

Steel

Surface

Zinc plated

Nominal drill-bit diameter (d 0)

10 mm

Drill hole depth (h 0)

25 mm

Effective anchoring depth (h ef)

25 mm

Torque during anchoring (T inst)

8 Nm

Through-hole in the component to be connected (d f)

9 mm

Minimum length of thread engagement Lsdmin ≤ [mm] 6 8 10 12
Torque while installing anchor Tinst ≤ [Nm] 4 8 15 35
Spacing between cavity axes lc ≥ [mm] 100
Spacing between tensioning strands lp ≥ [mm] 100
Spacing between tensioning strands and drill hole ap ≥ [mm] 50