Welcome to Würth Aerospace Solutions For trade customers only

Fixanchor W-FAZ/A4-U with large washer DIN EN ISO 7093-1 (DIN 9021)

Fixanchor W-FAZ w/ large washer stainless steel A4
ANC-(W-FAZ/A4)-WSH-A4-25-45-M16X145

Art.-no. 5928516025
EAN 4046777109733

Prices for customers after login
Fixanchor W-FAZ/A4-U with large washer DIN EN ISO 7093-1 (DIN 9021)

Art.-no. 5928516025

Prices for customers after login
Quantity
PU
x 20 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

Bolt anchor for high loads in cracked and non-cracked concrete. Stainless steel A4
  • High load-bearing capacities, low axial and edge clearance

  • Immediate load-bearing capacity - no waiting

  • Time-saving in-place installation

  • Torque-controlled expansion anchor made of stainless steel A4

  • Reduced effective anchorage depth

  • Minimised drilling and time requirements

  • Flexible application
Proof of Performance
  • Approval ETA-99/0011 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 (M8–M20)

  • Fire resistance (M8–M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)
Application area

Create the drill hole

10

Knock in anchor with mason's mallet or machine setting tool

Set anchor in place

Apply torque

  • Approval ETA-99/0011 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 (M8–M20)

  • Fire resistance (M8–M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Individual attachment with approval


Standard concrete C20/25 to C50/60 (cracked and non-cracked concrete, seismic performance category C1 and C2)


For the attachment, e.g. of metal structures, metal profiles, brackets, footplates, supports, cable conduits, pipes, railings, wooden structures, roof beams etc.



Individual attachment without approval


Can be used in concrete < C20/25 and compression-proof natural stone



W-FAZ/A4 (A4 stainless steel) approved for use in dry indoor areas and also outdoors (including industrial atmospheres and coastal areas) or in damp rooms, provided that no particularly aggressive conditions are present.

Metric anchor diameter

M16

Anchor length (l)

145 mm

Attachment height (t fix)

25 mm

Max. attachment height reduced (t fix, red)

45 mm

Effective anchoring depth (h ef)

85 mm

Effective anchoring depth reduced (h ef, red)

65 mm

Disc diameter x disc thickness

50 x 3 mm

Width across flats

24 mm

Nominal drill-bit diameter (d 0)

16 mm

Drill hole depth (h 1)

110 mm

Drill hole depth reduced (h 1, red)

90 mm

Material

Stainless steel A4, 1.4401

Torque during anchoring (T inst)

110 Nm

Through-hole in the component to be connected (d f)

18 mm

Approval

ETA-99/0011

Admissible load when exposed to fire (R30, R60, R90, R120) see European Technical Assessment ETA-99/0011
Characteristic values
Anchor diameter [mm]M8M10M12M16M20M24
Minimum edge distance
Non-cracked concrete
cmin ≥ [mm]504090657510090170__
Minimum edge distance
Cracked concrete
for s ≥ [mm]80185115180140250180250__
Minimum edge distance
Non-cracked concrete
for s ≥ [mm]10018514018015018520065__
Nominal drill diameterd0 [mm]81012162024
Diameter of cutting edgesdcut ≤ [mm]8,4510,4512,516,520,5524,55
Drill hole depthh1 ≥ [mm]60497555907011090125155
Through hole in the component being connecteddf ≤ [mm]91214182226
Torque while installing anchorTinst = [Nm]203550110200290
1) The partial safety factors of the resistances regulated in the approval and a partial safety factor of the effects of γF = 1.4 have been taken into account. Please refer to the European Technical Approval Guidelines (ETAG), Appendix C, for information on combining tensile and transverse loads, the influence of the edge distance and groups of anchors.
2)The concrete has normal reinforcement. Higher values are possible for higher concrete strengths.
3) Only suitable for use indoors or in wet rooms.
Standard effective anchorage depth/
Reduced effective anchorage depth

hef/hef,red [mm]
46353)604070508565100125
Axis distanceScr,N [mm]138105180120210150255195300375
Edge distanceCcr,N [mm]6952,5906010575127,597,5150187,5
Standard minimum member thicknesshstd ≥ [mm]100_120_140_160_200250
Minimum axis distance
Cracked concrete
smin ≥ [mm]40_50_60_60_95125
Minimum axis distance
Non-cracked concrete
smin ≥ [mm]40_50_60_65_90125
Minimum axis distance
Cracked concrete
for c ≥ [mm]70_75_100_100_150125
Minimum axis distance
Non-cracked concrete
for c ≥ [mm]80_75_120_120_180125
Minimum edge distance
Cracked concrete
cmin ≥ [mm]40_55_60_60_95125
Minimum edge distance
Non-cracked concrete
cmin ≥ [mm]50_60_75_80_130125
Minimum edge distance
Cracked concrete
for s ≥ [mm]80_90_140_180_200125
Minimum edge distance
Non-cracked concrete
for s ≥ [mm]100_120_150_150_240125
Reduced minimum member thicknesshmin [mm]808010080120100140140__
Minimum axis distance
Cracked concrete
smin ≥ [mm]4050455060507065__
Minimum axis distance
Non-cracked concrete
smin ≥ [mm]4050605060508065__
Minimum axis distance
Cracked concrete
for c ≥ [mm]706090100100160160170__
Minimum axis distance
Non-cracked concrete
for c ≥ [mm]8060140100120160180170__
Minimum edge distance
Cracked concrete
cmin ≥ [mm]40405065606580100__