Welcome to Würth Aerospace Solutions For trade customers only

Fixanchor W-FAZ/HCR

Fixanchor W-FAZ steel HCR
ANC-(W-FAZ/HCR)-HCR-20-40-M12X115

Art.-no. 5928612020
EAN 4056808276372

Prices for customers after login
Fixanchor W-FAZ/HCR

Art.-no. 5928612020

Prices for customers after login
Quantity
PU

Exclusively for trade customers

Register now and access more than 125,000 products

Bolt anchor for high loads in cracked and non-cracked concrete. Highly corrosion-resistant steel, HCR

High loads, low axial and edge clearances



Immediate load-bearing capacity


No waiting times



Time-saving push-through installation



Torque-controlled expanding anchor made of highly corrosion-resistant steel HCR



Fixing anchor cone with patented plastic coating


Safe expansion in cracked concrete



Reduced anchoring depth


  • Minimises drilling, time-saving

  • Flexible range of applications
Proof of Performance
  • Approval ETA-99/0011 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 (M8–M20)

  • Fire resistance (M8–M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)

  • Fire load to ZTV-ING Part 5 (uniform temperature curve – tunnel fire room curve)
Application area

Create the drill hole

10

Knock in anchor with mason's mallet or machine setting tool

Set anchor in place

Apply torque

  • Approval ETA-99/0011 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 (M8–M20)

  • Fire resistance (M8–M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)

  • Fire load to ZTV-ING Part 5 (uniform temperature curve – tunnel fire room curve)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Individual attachment with approval


Standard concrete C20/25 to C50/60 (cracked and non-cracked concrete, seismic performance category C1 and C2)


For the attachment, e.g. of metal structures, metal profiles, brackets, footplates, supports, cable conduits, pipes, railings, wooden structures, roof beams etc.



Individual attachment without approval


Can be used in concrete < C20/25 and compression-proof natural stone



W-FAZ/HCR (highly corrosion-resistant steel) can be used in areas where there is a very high risk of corrosion (e.g. indoor swimming pools, road tunnels, poorly ventilated car parks or parts in seawater and coastal atmospheres).

Metric anchor diameter

M12

Anchor length (l)

115 mm

Attachment height (t fix)

20 mm

Max. attachment height reduced (t fix, red)

40 mm

Effective anchoring depth (h ef)

70 mm

Effective anchoring depth reduced (h ef, red)

50 mm

Width across flats

19 mm

Nominal drill-bit diameter (d 0)

12 mm

Drill hole depth (h 1)

90 mm

Drill hole depth reduced (h 1, red)

70 mm

Material

High corrosion-resistant steel, 1.4529, X1NiCrMoCuN25-20-7

Torque during anchoring (T inst)

50 Nm

Through-hole in the component to be connected (d f)

14 mm

Approval

ETA-99/0011

Performance data
Anchor diameter [mm]M8M10M12M16M20M24
For admissible load when exposed to fire (R30, R60, R90, R120), please refer to European Technical Approval ETA-99/0011
Fire resistanceF30 [kN]9,0_15,0_19,0_30,0___
F60 [kN]5,0_9,0_12,0_15,0___
F90 [kN]1,8_4,0_5,0_7,5___
F120 [kN]1,0_2,0_3,0_6,0___
Standard effective anchorage depth/
Reduced effective anchorage depth

hef/hef,red [mm]
46353)604070508565100125
Admissible centric tension load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
Nadm [kN] = C20/252)2,42,44,33,67,66,111,99,017,119,0
Compressive zone (uncracked concrete C20/252) (scr,sp and ccr,sp,
see approval)
5,73,67,64,311,98,516,712,624,033,6
Admissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone (cracked concrete C20/252),
c ≥ 10 hef)
Vadm [kN] = C20/252)7,47,411,410,417,114,531,421,643,967,1
Compressive zone (uncracked concrete
C20/252),
c ≥ 10 hef)
7,47,411,411,417,117,131,430,243,970,6
Admissible bending momentMadm [Nm]14,914,929,729,752,6_114,3_231,6448,8
Characteristic values
Anchor diameter [mm]M8M10M12M16M20M24
Minimum axis distance
Uncracked concrete
for c ≥ [mm]80_75_120_120_180125
Minimum edge distance
Cracked concrete
cmin ≥ [mm]40_55_60_60_95125
Minimum edge distance
Uncracked concrete
cmin ≥ [mm]50_60_75_80_130125
Minimum edge distance
Cracked concrete
for s ≥ [mm]80_90_140_180_200125
Minimum edge distance
Uncracked concrete
for s ≥ [mm]100_120_150_150_240125
Reduced minimum member thicknesshmin [mm]808010080120100140140__
Minimum axis distance
Cracked concrete
smin ≥ [mm]4050455060507065__
Minimum axis distance
Uncracked concrete
smin ≥ [mm]4050605060508065__
Minimum axis distance
Cracked concrete
for c ≥ [mm]706090100100160160170__
Minimum axis distance
Uncracked concrete
for c ≥ [mm]8060140100120160180170__
Minimum edge distance
Cracked concrete
cmin ≥ [mm]40405065606580100__
Minimum edge distance
Uncracked concrete
cmin ≥ [mm]504090657510090170__
Minimum edge distance
Cracked concrete
for s ≥ [mm]80185115180140250180250__
Minimum edge distance
Uncracked concrete
for s ≥ [mm]10018514018015018520065__
Nominal drill diameterd0 [mm]81012162024
Drill cutting dia.dcut ≤ [mm]8,4510,4512,516,520,5524,55
Drill hole depthh1 ≥ [mm]60497555907011090125155
Through hole in the component being connecteddf ≤ [mm]91214182226
Torque while installing anchorTinst = [Nm]203550110200290
Standard effective anchorage depth/
Reduced effective anchorage depth

hef/hef,red [mm]
46353)604070508565100125
Embedment depthhnom [mm]5241684880609777114140
Axis distanceScr,N [mm]138105180120210150255195300375
Edge distanceCcr,N [mm]6952,5906010575127,597,5150187,5
Standard minimum member thicknesshstd ≥ [mm]100_120_140_160_200250
Minimum axis distance
Cracked concrete
smin ≥ [mm]40_50_60_60_95125
Minimum axis distance
Uncracked concrete
smin ≥ [mm]40_50_60_65_90125
Minimum axis distance
Cracked concrete
for c ≥ [mm]70_75_100_100_150125

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information