Inclined corner CERAfix 311/312
Inclined corner CERAfix
WTRPROFMEMBR-SLOPECRN(CERAFIX-312)-28-R
Register now and access more than 125,000 products
For load classes A and C according to building regulations tests and for water impact classes W0-I to W3-I according to DIN 18534 and the Central Federation of the German Building Trade's technical information leaflet "Compound sealing" (AIV).
- Protects inclined corners from mechanical damage.
- The inclined corner must only be glued or reworked with solvent-free products.
- Edge, field, building separation and movement joints must be carried over or integrated at the specified locations and suppressed (e.g. with edge strips).
- Larger product residues must be disposed of in their original packaging in accordance with the applicable regulations.
- Fully emptied packaging must be recycled accordingly.
The usage instructions are recommendations based on the tests we have conducted and on our experience; carry out your own tests before each application. Due to the large number of applications and storage and processing conditions, we do not assume any liability for a specific application result. If our free customer service provides technical information or acts as an advisory service, no responsibility is assumed by this service except where the advice or information given falls within the scope of our specified, contractually agreed service or the advisor was acting deliberately. We guarantee the consistent quality of our products. We reserve the right to make technical changes and further develop products. Please observe the technical data sheet!
Datasheets(X)
Surface pre-treatment:
The instructions for substrate preparation correspond to the specifications in the technical data sheet of the chosen sealant.
Material | Polyethylene film |
Assembly position | Right |
Height | 28 mm |
Width of side | 120 mm |
Colour | Red |
Limb length | 80 mm |
Thickness | 0.6 mm |
Min. processing temperature | -30 °C |
Max. processing temperature | 90 °C |
Max. temperature resistance | 90 °C |
Min. temperature resistance | -30 °C |
Ultraviolet resistance | 0 - not applicable |
Shelf life from production | 24 Month |
Conditions to maintain shelf life from production | cool and dry storage area, no exposure to sunlight and weather conditions |
Explanation - water impact classes: Water impact class according to test principles AIV-F | Water impact |
W0-l | Low: Areas with infrequent exposure to spray water |
W1-I | Moderate: Areas with frequent exposure to spray water or infrequent exposure to industrial water without intensification by accumulating water |
W2-l | High: Areas with frequent exposure to spray water and/or industrial water, especially occasionally intensified at ground level by accumulating water |
W3-l | Very high: Areas with very frequent or long-lasting effects from spray and/or industrial water and/or water from intensive cleaning processes, intensified by accumulating water |