Welcome to Würth Aerospace Solutions For trade customers only

TEGAfix® 400 jointing mortar

Joint mortar impermeable to water
JNT-(TEGAFIX-400)-WTRIMPER-ANTHR-25KG

Art.-no. 5875500502

EAN 4065746279697

Individual price display after login
TEGAfix® 400 jointing mortar

Art.-no. 5875500502

Individual price display after login
Quantity
PU

Exclusively for trade customers

Register now and access more than 125,000 products

Hydraulically wet-curing mortar for impermeable grouting of areas that are subjected to light to heavy loads

For grouting the joints in old and new paving, including in areas of extreme stress such as in the railway sector, road building and hydraulic engineering


  • N1-N3 in accordance with ZTV Wegebau (Supplementary Technical Conditions of Contract for the Construction of Paths and Public Spaces outside Areas of Road Traffic)

  • In accordance with FGSV (Road and Transportation Research Association) leaflet

  • In accordance with DIN EN 998-2 M20

  • In accordance with DIN 18580 NM IIa
Notice

Shelf life of 12 months when stored on wooden crates in a cool, dry place protected from the weather


Close containers again promptly after opening and use the product as quickly as possible



The technical data refers to +20°C and 50 % relative humidity. Lower temperatures increase the specified values, while higher temperatures decrease the specified values.


Factors such as differences in how moist the substructure and the jointing mortar or surrounding environment is in places can cause differences in colour. We cannot assume any liability for colour deviations such as these or similar in the joint network created.


The properties of the stone may cause a thin film to remain after grouting.


Always prepare a test surface!


Vessels and tools etc. must be cleaned immediately with water, as once the material has hardened, cleaning can only be carried out mechanically.


Set mortar must not be mixed with water again.

The usage instructions are recommendations based on the tests we have conducted and on our experience; carry out your own tests before each application. Due to the large number of applications and storage and processing conditions, we do not assume any liability for a specific application result. Insofar as our free customer service provides technical information or acts as an advisory service, no responsibility is assumed by this service except where the advice or information given falls within the scope of our specified, contractually agreed service or the advisor was acting with deliberate intent. We guarantee the consistent quality of our products. We reserve the right to make technical changes and further develop products. Please observe the technical data sheet!

Product information

Datasheets(X)

Safety data sheet

Certificates/ Documents

 | 

 | 

Application area

For grouting the joints in old and new paving, including in areas of extreme stress such as in the railway sector, road building and hydraulic engineering


  • N1-N3 in accordance with ZTV Wegebau (Supplementary Technical Conditions of Contract for the Construction of Paths and Public Spaces outside Areas of Road Traffic)

  • In accordance with FGSV (Road and Transportation Research Association) leaflet

  • In accordance with DIN EN 998-2 M20

  • In accordance with DIN 18580 NM III a
Instructions

Carefully mix the jointing mortar with 5 - 5.5 litres of clean tap water in a clean mixing vessel for 3 minutes to create a lump-free consistency. We recommend using a 600 rpm mixer to do this. Give the product approximately 2 minutes to mature, then stir through again before applying.


Pre-wet the surface and spread the compound over the top, working it into the joints using a rubber squeegee or similar tool and taking care to avoid trapping air pockets. The surface must be kept moist with spray mist while the material is setting.


Once the material has set (i.e. the material in the joint can no longer be pressed in with a finger), wet the surface, pre-clean it with a hard brush (scrubbing brush) and then wait approximately 10 minutes before washing it thoroughly.


High temperatures decrease the specified times, while high temperatures increase the specified times.

Chemical basis

Cement, classified as sand

Colour

Anthracite

May be walked on after max.

3 h

May be walked on in following conditions

at 20°C and 50% relative humidity

Min. processing temperature

5 °C

Max. processing temperature

30 °C

Min. application quantity in weight/area

1.9 kg/m²

Max. application quantity in weight/area

11.1 kg/m²

Application quantity conditions

for 3-mm joint width

Weight of content

25 kg

Min. compressive strength

12 N/cm²

Shelf life from production

12 Month

Conditions to maintain shelf life from production

cool and frost-free storage area, in sealed original container

Colours Grey, anthracite, dark grey
Water requirements Approx. 5 - 5.5 l per 25 kg container
Coverage 2.05 kg/dm³
Maturing time at 20°C Approx. 2 mins
Application time at 20°C Approx. 20 mins
Can be walked on at 20°C After approx. 3 hrs
Can be fully loaded at 20°C After approx. 7 days
Application temperature > +5°C to +25°C
Temperature resistance Approx. -30°C to +80°C
Joint width From 6 mm to 50 mm
Young's modulus, static Approx. 24,000 N/mm²
Joint depth > 4 cm
Compressive strength
After 24 hrs Approx. 20 N/mm² (20°C)
After 7 days Approx. 50 N/mm² (20°C)
After 28 days Approx. 60 N/mm² (20°C)
Tensile bending strength
After 24 hrs Approx. 4 N/mm² (20°C)
After 7 days Approx. 6.5 N/mm² (20°C)
After 28 days Approx. 9 N/mm² (20°C)
Suitable glove:
 
Product
Description
Household glove
Household glove
Description:
Permeation level: 6
Liquid-proof, premium-quality cleaning glove made from natural latex
Vinyl chemical and moisture protective glove
Vinyl chemical and moisture protective glove
Description:
Permeation level: 6
Fully dipped protective glove with vinyl coating on cotton jersey lining
Chemical protective glove, Butyl
Chemical protective glove, Butyl
Description:
Permeation level: 6
Gas-tight and resistant to exhaust gases produced by combustion processes
Chemical protective glove PVC w. backing fabric
Chemical protective glove PVC w. backing fabric
Description:
Permeation level: 6
Very robust, submersible PVC glove with cotton support fabric
Chemical protective glove made from chloroprene and latex
Chemical protective glove made from chloroprene and latex
Description:
Permeation level: 6
Cotton flocking on the inside
Nitrile chemical protective glove with cotton velour finish inside
Nitrile chemical protective glove with cotton velour finish inside
Description:
Permeation level: 6
Nitrile chemical protective glove long, heavy-duty design
Nitrile chemical protective glove long, heavy-duty design
Description:
Permeation level: 6
Chemical protective glove chloroprene
Chemical protective glove chloroprene
Description:
Permeation level: 6
Heavy-duty design
Chemical protective glove nitrile with backing fabric
Chemical protective glove nitrile with backing fabric
Description:
Permeation level: 6
Robust, liquid-tight protective glove with polyamide support fabric that combines optimum chemical protection, secure grip and comfort
Disposable nitrile glove
Disposable nitrile glove
Description:
Permeation level: 6
Liquid-proof, food-safe disposable glove
Disposable nitrile grip glove
Disposable nitrile grip glove
Description:
Permeation level: 6
Unique, diamond texture for optimal grip
Disposable glove Nitrile Grip Comfort
Disposable glove Nitrile Grip Comfort
Description:
Permeation level: 6
Very robust disposable gloves with excellent grip thanks to special nubs and maximum wearing comfort thanks to cotton flocking inside
Disposable gloves, nitrile, extra strong, type A
Disposable gloves, nitrile, extra strong, type A
Description:
Permeation level: 6
Durable and robust disposable gloves with excellent chemical protection
Permeation is the process by which a chemical moves through the material of a protective glove on a molecular level. The time from the initial contact between the chemical and the glove to the permeation of the material is the breakthrough time.
Measured breakthrough time
Permeation level
< 10 min
0
≥ 10 min
1
≥ 30 min
2
≥ 60 min
3
≥ 120 min
4
≥ 240 min
5
≥ 480 min
6

Important information:

The information given is based on experience and laboratory conditions and is designed as a guide. However, the actual suitability of a glove depends on the individual conditions of its use and must be confirmed by an appropriate test under operational conditions. Given the variety of materials and chemicals used, the possibility of incompatibility or usage problems for the wearer cannot be excluded in individual cases. We would be happy to advise you about optimum solutions.

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information