Welcome to Würth Aerospace Solutions For trade customers only

W-FAZ/S-UH Fixanchor with large washer for timber construction DIN EN ISO 7094 (DIN 440)

Fixanchor W-FAZ/S with large washer/wood cons.
ANC-(W-FAZ/S)-WSH-(A2K)-105-125-M12X200

Art.-no. 5928362105
EAN 4046777090017

Prices for customers after login
W-FAZ/S-UH Fixanchor with large washer for timber construction DIN EN ISO 7094 (DIN 440)

Art.-no. 5928362105

Prices for customers after login
Quantity
PU
x 25 pcs

Exclusively for trade customers

Register now and access more than 125,000 products

Bolt anchor for the timber constructions, suitable for high loads in cracked and non-cracked concrete. Zinc-plated steel
  • High loads, small axis and edge distances

  • Immediate load-bearing capacity – no waiting times

  • Time-saving push-through installation
Proof of Performance
  • Approval ETA-99/0011 for individual attachment, option 1, cracked and non-cracked concrete

  • Fire resistance (M12 - M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)
Application area

Create the drill hole

10

Knock in anchor with mason's mallet or machine setting tool

Set anchor in place

Apply torque

  • Approval ETA-99/0011 for individual attachment, option 1, cracked and non-cracked concrete

  • Fire resistance (M12 - M16): F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (uniform temperature-time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-99/0011)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area

Single mounting with approval


Normal concrete C20/25 to C50/60 (cracked and non-cracked concrete)


Optimal for mounting wood constructions, bars, etc.



Individual attachment without approval


Can be used in concrete < C20/25 and compression-proof natural stone



W-FAZ/S approved only for use in dry indoor room conditions

Metric anchor diameter

M12

Anchor length (l)

200 mm

Attachment height (t fix)

105 mm

Max. attachment height reduced (t fix, red)

125 mm

Effective anchoring depth (h ef)

70 mm

Effective anchoring depth reduced (h ef, red)

50 mm

Disc diameter x disc thickness

44 x 4 mm

Width across flats

19 mm

Nominal drill-bit diameter (d 0)

12 mm

Drill hole depth (h 1)

90 mm

Drill hole depth reduced (h 1, red)

70 mm

Material

Steel

Surface

Zinc plated

Torque during anchoring (T inst)

45 Nm

Through-hole in the component to be connected (d f)

14 mm

Approval

ETA-99/0011

Performance data
Anchor diameter [mm]M8M10M12M16M20M24M27
Fire resistance ratingF30 [kN]2,0-5,6-9,0-16,0----
F60 [kN]1,0-2,2-3,5-7,0----
F90 [kN]0,65-1,3-2,0-4,3----
F120 [kN]0,5-0,8-1,3-3,0----
Standard effective anchorage depth/
Reduced effective anchorage depth

hef/hef,red [mm]
46353)604070508565100115125
Admissible centric tension load1)
on an individual anchor without the influence of the edge distance
Tensile zone
(cracked concrete C20/252),
s ≥ 3 hef c ≥ 1.5 hef)
Nadm [kN] = C20/252)2,42,44,33,67,66,111,99,017,121,124,0
Compressive zone (uncracked concrete C20/252) (scr,sp and ccr,sp,
see approval)
5,73,67,64,311,98,516,712,624,029,733,6
Admissible shear load1)
on an individual anchor without the influence of the edge distance
Tensile zone (cracked concrete C20/252),
c ≥ 10 hef)
Vadm [kN] = C20/252)7,07,011,510,417,114,531,421,637,159,267,1
Compressive zone (uncracked concrete
C20/252),
c ≥ 10 hef)
7,07,011,511,517,117,131,430,237,165,194,1
Admissible bending momentMadm [Nm]13,113,126,926,946,946,9123,4123,4195,0513,1760,9
For admissible load when exposed to fire (R30, R60, R90, R120), please refer to European Technical Assessment ETA-99/0011
Characteristic values
Anchor diameter [mm]M8M10M12M16M20M24M27
Minimum edge distance
Cracked concrete
cmin ≥ [mm]40_45_60_60_95100180
Minimum edge distance
Uncracked concrete
cmin ≥ [mm]50_50_75_80_130100180
Minimum edge distance
Cracked concrete
for s ≥ [mm]80_90_140_180_200220540
Minimum edge distance
Uncracked concrete
for s ≥ [mm]100_100_150_150_240220540
Reduced minimum member thicknesshmin [mm]808010080120100140140---
Minimum axis distance
Cracked concrete
smin ≥ [mm]4050455060507065---
Minimum axis distance
Uncracked concrete
smin ≥ [mm]4050605060508065---
Minimum axis distance
Cracked concrete
for c ≥ [mm]706090100100160160170---
Minimum axis distance
Uncracked concrete
for c ≥ [mm]8060140100120160180170---
Minimum edge distance
Cracked concrete
cmin ≥ [mm]40405065606580100---
Minimum edge distance
Uncracked concrete
cmin ≥ [mm]504090657510090170---
Minimum edge distance
Cracked concrete
for s ≥ [mm]80185115180140250180250---
Minimum edge distance
Uncracked concrete
for s ≥ [mm]10018514018015018520065---
Nominal drill diameterd0 [mm]8101216202428
Drill cutting dia.dcut ≤ [mm]8,4510,4512,516,520,5524,5528,55
Drill hole depthh1 ≥ [mm]60497555907011090125145160
Through hole in the component being connecteddf ≤ [mm]9121418222630
Torque while installing anchorTinst = [Nm]20254590160200300
Standard effective anchorage depth/
Reduced effective anchorage depth

hef,/hef, red [mm]
46 353)604070508565100115125
Embedment depthhnom [mm]5241684880609777114133146
Axis distanceScr,N [mm]138105180120210150255195300345375
Edge distanceCcr,N [mm]6952,5906010575127,597,5150172,5187,5
Standard minimum member thicknesshstd ≥ [mm]100_120_140_170_200230250
Minimum axis distance
Cracked concrete
smin ≥ [mm]40_45_60_60_95100125
Minimum axis distance
Uncracked concrete
smin ≥ [mm]40_45_60_65_90100125
Minimum axis distance
Cracked concrete
for c ≥ [mm]70_70_100_100_150180300
Minimum axis distance
Uncracked concrete
for c ≥ [mm]80_70_120_120_180180300

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information